Skip to main content

AI-POWERED DOCS

What do you want to know?

Pinouts (M12 & Terminal)

This page provides complete pinout details for the OV10i smart camera's connectors, including the 17-pin M12 Power & I/O interface and the M12 X-coded Ethernet port.


M12 A-Coded 17-Pin: Power & I/O Connector

The OV10i uses a male M12 17-pin connector for power, digital I/O, and reset functionality.

Pin Layout

PinSignal NameFunction
5, 6Power GND0V return path
7DIO GNDGround return for digital I/O
8Digital Input 0NPN logic input
9Digital Input 1NPN logic input
10Digital Output 0NPN open collector
11Digital Output 1NPN open collector
12RS232 RX (optional)Not used in standard configuration
13, 14Power VIN (+24 VDC)Primary power supply input
15Reset InputPull low to reboot
16Trigger InputNPN trigger or dry contact
OthersReserved / NCNot electrically connected
note

Pins 5, 6, 13, and 14 are required for powering the device.


M12 X-Coded Ethernet Connector

This 8-pin connector supports Gigabit Ethernet.

PinSignalFunction
1TD+Transmit Data (+)
2RD+Receive Data (+)
3TD-Transmit Data (-)
4RD-Receive Data (-)
5-8Bi-DirectionalGigabit pairs
note

Use an X-coded M12 Ethernet cable for connectivity.


Wire Color Reference (M12 17-Pin)

PinSignalWire ColorFunction
5GNDPink (PK)Power Ground
6GNDYellow (YE)Power Ground
7DIO GNDBlack (BK)Digital I/O Ground
8DI0Gray (GY)Digital Input 0 - NPN Active Low
9DI1Red (RD)Digital Input 1 - NPN Active Low
10DO0Violet (VT)Digital Output 0 - NPN Sinking
11DO1Orange (OG)Digital Output 1 - NPN Sinking
13Vin+Light Blue (LTBU)Power Input Positive (19-24V)
14Vin+Black/White (BKWH)Power Input Positive (19-24V)
15ResetBrown/White (BNWH)System Reset - NPN Active Low
16TriggerRed/White (RDWH)Trigger Input - NPN Active Low
1,2,3,4,12,17Reserved-Not connected

Digital I/O Electrical Summary

TypeLogicTrigger MethodCurrent Limit
Trigger InputNPN-compatiblePull to GND-
Digital InputsNPN-compatiblePull to GND-
Digital OutputsNPN Open CollectorPulls to GND when active100 mA per line
warning

Digital outputs (DO0 / DO1) are NPN open-collector, sinking only. They pull the line to GND when active and cannot source +24 V. An external pull-up or load to +24 V must be provided for proper operation.

note

Always tie DIO GND (Pin 7) to your system or PLC ground.


Power Wiring

Dual Power Input Design:

  • Pin 13 & 14: Both connected to Vin+ (19-24V positive)
  • Pin 5 & 6: Both connected to GND (power ground)
  • Dual connections provide redundancy and ensure consistent voltage across components
note

If there is insufficient power, modify the wiring to ensure that the 24V power supply is connected to both Vin+ ports (pins 13 & 14), rather than only connecting it to a single terminal.


Best Practices

  • Use M12 screw-lock cables rated for industrial use
  • Verify wiring polarity before powering up
  • Add ferrules or strain reliefs in control panels
  • Never hot-swap the M12 Power/I/O connector