Digital Input Setup

This guide shows you how to configure the OV20i's digital inputs to initiate camera inspections from external devices. The camera has 2 digital inputs that detect True/False signals from sensors, switches, PLCs, or other automation equipment.

When to Use Digital Inputs: Automated production lines with sensors, manual control switches, PLC-controlled inspections, conveyor belt integration, or any external device that needs to signal the camera to start an inspection.

Prerequisites

  • OV20i camera system set up and connected
  • Active recipe configured with imaging and inspection setup
  • External input device (sensor, switch, PLC output, etc.)
  • Understanding of NPN digital input wiring
  • M12 connector access for wiring

Digital Input Specifications

The OV20i provides 2 digital inputs accessible via the M12 connector:

InputPin #Wire ColorFunction
Digital Input 18OrangeConfigurable control input
Digital Input 29WhiteConfigurable control input

Operating Logic:

  • NPN Input Type: Common ground switching
  • True (ON): Input connected to ground (0V)
  • False (OFF): Input open or at 24V
  • Signal Voltage: 24V DC nominal

Digital Input Wiring

NPN Wiring Configuration

Standard NPN sensor connection:

+24V ──→ Sensor Power
Ground ──→ Common Ground
Sensor Output ──→ Camera Digital Input Pin

Important

The OV20i uses NPN inputs, which means the input goes True when connected to ground.

Use Node-RED to access the signal from the input nodes.